Polaris Renewable Solutions Pvt. Ltd.

Utility-Scale Solar

Engineering, civil, electrical and HT evacuation under one point of responsibility, so no interface slips between contractors.

Ground-mounted solar plant delivered by Polaris
1.10 MWp · Shriram Stone Crusher

Outcomes

One accountable partner

Civil, mechanical and electrical under one contract.

Grid connection planned from day one

Evacuation is on the critical path, not an afterthought.

Built for hard sites

Rock, dust, monsoon and remote logistics.

Scope

Full EPCDesign, supply, construction and commissioning of the whole plant.15 items
  • Project engineeringFeasibility, front-end engineering, layouts, detailed design and energy-yield studies
  • Civil & site developmentSurvey coordination, earthworks, grading, foundations, piling, trenches and roads
  • Mechanical executionAssembly and alignment of tracker or fixed-tilt structures, module installation
  • Electrical & power systemsDC/AC networks, inverters, transformers, switchgear, MV/HT systems
  • SCADA & grid integrationMonitoring and controls, evacuation systems, grid synchronisation
  • Testing & commissioningPre-commissioning, documentation, handover and final performance checks
  • Substation civil worksFoundations and equipment support structures
  • HT switchgear11 kV / HT switchgear and panels
  • TransformersAnd associated electrical equipment
  • HT cablingPower cables, cable trenches and termination systems
  • Protection & controlProtection, control and metering panels
  • Earthing & lightning protectionSystems built to code
  • AC auxiliary systemsSupporting the plant's electrical needs
  • Cable worksLaying, glanding, termination, identification and ferruling
  • Electrical testingProtection testing, pre-commissioning and commissioning support
BOS onlyEverything except modules and inverters.15 items
  • Project engineeringFeasibility, front-end engineering, layouts, detailed design and energy-yield studies
  • Civil & site developmentSurvey coordination, earthworks, grading, foundations, piling, trenches and roads
  • Mechanical executionAssembly and alignment of tracker or fixed-tilt structures, module installation
  • Electrical & power systemsDC/AC networks, inverters, transformers, switchgear, MV/HT systems
  • SCADA & grid integrationMonitoring and controls, evacuation systems, grid synchronisation
  • Testing & commissioningPre-commissioning, documentation, handover and final performance checks
  • Substation civil worksFoundations and equipment support structures
  • HT switchgear11 kV / HT switchgear and panels
  • TransformersAnd associated electrical equipment
  • HT cablingPower cables, cable trenches and termination systems
  • Protection & controlProtection, control and metering panels
  • Earthing & lightning protectionSystems built to code
  • AC auxiliary systemsSupporting the plant's electrical needs
  • Cable worksLaying, glanding, termination, identification and ferruling
  • Electrical testingProtection testing, pre-commissioning and commissioning support
Electrical & evacuationSubstation, HT switchgear, transformers, cabling, protection, earthing.12 items
  • Electrical & power systemsDC/AC networks, inverters, transformers, switchgear, MV/HT systems
  • SCADA & grid integrationMonitoring and controls, evacuation systems, grid synchronisation
  • Substation civil worksFoundations and equipment support structures
  • HT switchgear11 kV / HT switchgear and panels
  • TransformersAnd associated electrical equipment
  • HT cablingPower cables, cable trenches and termination systems
  • Protection & controlProtection, control and metering panels
  • Earthing & lightning protectionSystems built to code
  • AC auxiliary systemsSupporting the plant's electrical needs
  • Cable worksLaying, glanding, termination, identification and ferruling
  • Electrical testingProtection testing, pre-commissioning and commissioning support
  • Testing & commissioningPre-commissioning, documentation, handover and final performance checks

O&M

SCADA monitoring, preventive maintenance and performance reporting.

How it works

FAQ

What project sizes do you take on?

Tell us the capacity, site location and grid connection point, and we will confirm whether it is a fit and how we would scope it. Our ground-mounted portfolio includes captive plants of around 1 MWp.

Can you do BOS only if we supply modules and inverters?

Yes. BOS only covers everything except modules and inverters, which you supply: engineering, civil, mechanical and electrical works, evacuation and commissioning.

Do you handle evacuation approvals and utility liaison?

Yes. Grid integration is part of our scope: the evacuation line, the substation interface and liaison for the approvals involved. It is planned from day one, because evacuation sits on the critical path.

How do you manage monsoon and remote-site logistics?

By engineering for them at the start. The site and grid study comes first, followed by a geotechnical survey, site-specific foundation and drainage design, and a construction plan that accounts for the monsoon window and access to the site.

Do you offer O&M after commissioning?

Yes. O&M is a separate package: SCADA monitoring, preventive maintenance and performance reporting, so the plant keeps delivering after handover.

Commercial & Industrial

On-site and off-site solar, storage and electrical solutions built around industrial load profiles, site conditions and savings goals.

Learn more

Finance Solutions

CAPEX, OPEX / RESCO, captive, lease and financing support aligned with your capital, cash-flow and return priorities.

Learn more

Energy Optimisation Consultant

A practical energy plan based on load, tariff, solar, storage, demand management and power-sourcing analysis.

Learn more